HRU Komfovent Domekt R450V panel C6.1
Komfovent Domekt R450V recuperator with C6.1 panel Even at outside temperatures below -20°C, additional heating of fresh air is not necessary, which results in significant savings in thermal energy even in severe frosts. The use of a rotary heat exchanger reduces the energy consumption for heating the supply air by about four times.
Reviews | |
Shipping within | 48 hours |
Shipping price | The Lack Of |
The Availability Of | Duża dostępność 900 opak |
The Weight Of The | 45 kg |
The bar code | 5904326322851 |
EAN | 5904326322851 |
Phone orde SMS: +48606376838
CONTROL UNIT RECUPERATOR KOMFOVENT DOMEKT R 450V
WITH CONTROL WALL PANEL C6.1
Advantages of the Domekt R series
Heat energy saving In the process of room ventilation, the heat from the exhaust air is transferred to the supply air.
Efficient heating
Under normal operating conditions, the rotary heat exchanger does not freeze. Even at outside temperatures below -20°C, additional heating of the fresh air is not necessary, resulting in significant savings in thermal energy even in severe frosts. The use of a rotary heat exchanger reduces the energy consumption for heating the supply air by about four times.
Moisture balance in the air
Under normal operating conditions, there is no condensation on the rotary heat exchanger, as most of it is returned to the rooms. Excess moisture is drained to the outside. The air in the rooms does not dry out and the appropriate humidity is maintained. Since no condensate is formed, a condensate drain is also not needed, which simplifies the installation of the unit.
Low noise level
Domekt R air handling units are equipped with low-noise fans and soundproofing insulation, which ensure quiet operation of the units.
Advantages of rotary heat exchanger
- High Efficiency
- No freezing
- Four times less energy consumption for heating the supplied air.
- Transfer of moisture to the supplied air - the use of additional humidifiers in ventilated rooms is not necessary.
- No condensate drain is needed - easy installation of the unit.
- Possibility of cooling recovery, and therefore lower energy consumption for air cooling.
Efficiency: Rotary heat exchangers are offered in two efficiency levels. Standard, optimal efficiency is provided by the L-type heat exchanger, while higher efficiency coefficients are achieved by the XL type heat exchangers.
Dimensions:
IMPORTANT: PLEASE CONFIRM THE VERSION:LEFT OR RIGHT WHEN ORDERING
Specifications:
Maximum air flow (m3/h) | 496 |
Maximum Air Flow (Fox) | 138 |
Rated Air Flow (m3/s) | 0,096 |
Rated Differential Pressure (Pa) | 50 |
JPM (W/(m3/h)) | 0,3 |
Temperature efficiency of heat recovery (%) | 86 |
Electric heater power (kW) / At (oc) | 1/8,5 |
Rated Voltage (V) | 1-230 |
Maximum load current HE (A) | 7,5 |
Power cord (mm2) | 3)<1.5 |
Power consumption of fan drive at maximum flow (W) | 147 |
Power Consumption of Fan Drive at Rated Flow (W) | 55 |
Sound power level, LWA, dB(A) | 38 |
Sound pressure level, Lm, dB(A) (3 m) | 28 |
Filter dimensions BxHxL (mm) | 517x278x46 |
Unit Dimensions BxHxL (mm) | 585x655x680 |
Required operating space (mm) | 700 |
Weight (kg) | 60 |
-