banner_wyszukiwarka.jpg
  • HRU Komfovent Domekt R300V panel C6.1

The Symbol : 8766943308

Komfovent Domekt R300V recuperator with C6.1 panel Advantages of Domekt R series AHUs Saving thermal energy In the process of room ventilation, the heat from the exhaust air is transferred to the supply air.

12900.00
opak Add to wishlist
Reviews
Shipping within 24 hours
Shipping price The Lack Of
The Availability Of Duża dostępność
The Weight Of The 45 kg
EAN 5904326322875

Phone orde SMS: +48606376838

KOMFOVENT DOMEKT R 300V RECUPERATOR CONTROL PANEL WITH C6.1 CONTROL PANEL

Advantages of the Domekt R series

Heat energy saving In the process of room ventilation, the heat from the exhaust air is transferred to the supply air.

Efficient heating

Under normal operating conditions, the rotary heat exchanger does not freeze. Even at outside temperatures below -20°C, additional heating of the fresh air is not necessary, resulting in significant savings in thermal energy even in severe frosts. The use of a rotary heat exchanger reduces the energy consumption for heating the supply air by about four times.

Moisture balance in the air

Under normal operating conditions, there is no condensation on the rotary heat exchanger, as most of it is returned to the rooms. Excess moisture is drained to the outside. The air in the rooms does not dry out and the appropriate humidity is maintained. Since no condensate is formed, a condensate drain is also not needed, which simplifies the installation of the unit.

Low noise level

Domekt R air handling units are equipped with low-noise fans and soundproofing insulation, which ensure quiet operation of the units.

Advantages of rotary heat exchanger

  • High Efficiency
  • No freezing
  • Four times less energy consumption for heating the supplied air.
  • Transfer of moisture to the supplied air - the use of additional humidifiers in ventilated rooms is not necessary.
  • No condensate drain is needed - easy installation of the unit.
  • Possibility of cooling recovery, and therefore lower energy consumption for air cooling.

Efficiency: Rotary heat exchangers are offered in two efficiency levels. Standard, optimal efficiency is provided by the L-type heat exchanger, while higher efficiency coefficients are achieved by the XL type heat exchangers.

Specifications:

Maximum air flow (m3/h) 311
Maximum Air Flow (I/s) 86
Rated Air Flow (m3/s) 0,061
Rated Differential Pressure (Pa) 50
JPM (W/(m3/h)) 0,29
Temperature efficiency of heat recovery (96) 85
Electric heater power (kW) / At (oc) 0,5/6,7
Rated Voltage (V) 1-230
Maximum load current HE (A) 3,9
Power cord (mm2) 3>(1.5
Power consumption of fan drive at maximum flow (W) 78
Power Consumption of Fan Drive at Rated Flow (W) 34
Sound power level, LWA, dB(A) 40
Sound pressure level, Lm, dB(A) (3 m) 29
Filter dimensions BxHxL (mm) 290x205x46
Unit Dimensions BxHxL (mm) 515x615x605
Required operating space (mm) 610
Weight (kg) 29

 

Dimensions:

IMPORTANT: PLEASE CONFIRM THE VERSION: LEFT OR RIGHT WHEN ORDERING

image
image
Brand:
Komfovent
Packaging Condition:
oryginalne
Status:
New
Waga produktu z opakowaniem jednostkowym:
60 (2)
There is currently no comments or ratings for this product.
  • Rate

The Whole Thing
The Functionality Of The
Price
The Signature Of The
Opinion Of The
The Signature Of The
Email
Ask a question